Water in your diesel grade creating havoc?

Articles

Water in your diesel grade creating havoc?

Share this article

Reed Leighton, CEO

Diesel is a widely used fuel across the globe and the most commonly used fuel for back-up power supply. In recent years, as a result of heightened regulatory measures to decrease greenhouse gas emissions and reduce reliance on fossil fuels, the composition of diesel has changed. Mandates such as the reduction of sulphur in diesel leading to the release of ultra low sulphur diesel (ULSD) and the blending of biodiesel have altered both the make-up of diesel fuel, as well as the design of engines.

The most significant implication of these changes is that diesel absorbs a lot more water than it used to, leading to significant degradation in performance and usability if not managed properly. ULSD and biodiesel blends can bond so thoroughly to water that they emulsify, becoming thicker and milky in appearance, as seen in the “before” images below.

Traditional filters and centrifugal purifiers cannot easily remove the water. As mentioned in a previous blog – Water is the Enemy – these newer forms of diesel are also particularly susceptible to microbial growth as a result of the higher water content. Furthermore, the engines of today are increasingly intolerant to the introduction of water and particulate matter in their systems.

Particularly considering diesel’s critical role in emergency power generation, this exposes the industry to considerable operational and reputation risk, unless fuel companies proactively monitor for water and sediment build-up and clean diesel to prevent degradation.

Leighton O’Brien proactively works with our clients to assist them with comprehensive diesel management strategies, encompassing monitoring, testing and cleaning. Just last week we helped another Australian client restore milky diesel to a high quality state as per the attached images.

The following multi-stage tank cleaning process was applied to their diesel tanks:

  • Take a fuel sample from the tank bottom, prior to cleaning and give sample a haze rating.
  • Remove water and particulate from the tank floor and separate waste products.
  • Treat the remaining fuel to remove particulate matter and free water with the 
multi-stage filtration and conditioning system.
  • Continue circulating the fuel through the filtration and conditioning system to 
address degradation and polymerisation until satisfactory visual samples that meet ASTM D 4176 test pass requirements can be taken.
  • Line flush from all nozzles to ensure the system from tank to nozzle contains clean product. Product is returned to tank via filtration system.
  • Take nozzle sample to ensure product meets visual specification.

Related News & Insights

  • 16.01.2023
  • Cleaning
Water in your underground storage tank is the enemy
Read more
An alternative to Hydro Testing: Dri-sump® Containment Tightness Testing
  • 05.01.2023
  • Compliance Plus
Changing the status quo on UST containment testing: How you can improve compliance and conserve water, not contaminate it
Read more
Chris Cooper Leighton O'Brien - Highlights 2022
  • 21.12.2022
  • iHUB
A great summary of 2022 by our CEO Chris Cooper
Read more
  • 18.12.2022
  • Tank & Line Testing
Why E10 gas & early fibreglass tanks don’t mix
Read more
Clay Moore, Sr Director of Product at Leighton O'Brien
  • 02.12.2022
  • iHUB
Staff spotlight series: Clay Moore
Read more
iHUB alarm management - maximize ATG Investment - Leighton O'Brien
  • 28.11.2022
  • AMS, iHUB
Get smart about your Automatic Tank Gauge investment
Read more